List of products by brand J + J

J+J Automation logo

Tameson has partnered with J+J Automation to be a distributor of their electric actuators. J+J Automation is a leading global manufacturer and provider of electric actuators and services. Tameson's full J+J Automation product offering and support is listed below. If you are looking for a J+J Automation product that is not listed below, contact us.

Product Brand Voltage ISO 5211 Flange type Control signal Model Torque (Nm) Nominal power (VA) Manual override Material Operating time (s) ISO 5211 Square head size (mm) Position feedback Max. angle of rotation (°) Suitable for air accessory Width (mm) Transmission With safety function Suitable for valve ISO 5211 Direct Mount top flange Degree of protection (IP) Adjustable operating range Ambient temperature (°C) Height (mm) Explosion-proof Duty cycle End contacts Regulation type on/off Regulation type modulating With mechanical setting indicator Regulation type splitrange Deactivated when closed Max. electric power input (VA) Potential free switch contact Principle of operation safety function Type of safety function
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Flange F03, Flange F04,... 4-20 mA (modulating) Rotating 20 22.2 Yes Polyamide (PA) 10 11 4-20 mA, Open & close limit... 90 No 110 With cogwheels No Yes Yes IP67 Yes -20 °C to 70 °C 171 No 75% 2 No Yes Yes No No 39.6 Yes - -
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Flange F05, Flange F07 4-20 mA (modulating) Rotating 55 21.1 Yes Polyamide (PA) 15 14 4-20 mA, Open & close limit... 90 No 110 With cogwheels No Yes Yes IP67 Yes -20 °C to 70 °C 196 No 75% 2 No Yes Yes No No 48 Yes - -
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Flange F03, Flange F04,... Three-point (open-close) Rotating 35 22.7 Yes Polyamide (PA) 10 11 None 90 No 110 With cogwheels Yes Yes Yes IP67 Yes -20 °C to 70 °C 171 No 75% 2 Yes No Yes No No 45.9 Yes Fail-safe (NO / NC, depends... Electronic
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Flange F05, Flange F07 Three-point (open-close) Rotating 55 21.1 Yes Polyamide (PA) 15 17 None 90 No 110 With cogwheels Yes Yes Yes IP67 Yes -20 °C to 70 °C 196 No 75% 2 Yes No Yes No No 48 Yes Fail-safe (NO / NC, depends... Electronic
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Flange F03, Flange F04,... Three-point (open-close) Rotating 20 22.2 Yes Polyamide (PA) 10 11 None 90 No 110 With cogwheels Yes Yes Yes IP67 Yes -20 °C to 70 °C 171 No 75% 2 Yes No Yes No No 39.6 Yes Fail-safe (NO / NC, depends... Electronic
J3C Modulating 85-240V...
+9 days
J + J 120 V AC, 230 V AC Flange F07, Flange F10 4-20 mA (modulating) Rotating 300 - Yes Polyamide (PA) 58 22 4-20 mA, Open & close limit... 90 No 214 With cogwheels No Yes Yes IP67 Yes -20 °C to 70 °C 254 No 75% 2 No Yes Yes No No 79.4 Yes - -
J3C Modulating Fail-Safe...
+9 days
J + J 120 V AC, 230 V AC Flange F07, Flange F10 4-20 mA (modulating) Rotating 140 - Yes Polyamide (PA) 58 22 4-20 mA, Open & close limit... 90 No 214 With cogwheels Yes Yes Yes IP67 Yes -20 °C to 70 °C 254 No 75% 2 No Yes Yes No No 68.2 Yes Fail-safe (NO / NC, depends... Electronic
J3C Modulating Fail-Safe...
+9 days
J + J 120 V AC, 230 V AC Flange F07, Flange F10 4-20 mA (modulating) Rotating 300 - Yes Polyamide (PA) 58 22 4-20 mA, Open & close limit... 90 No 214 With cogwheels Yes Yes Yes IP67 Yes -20 °C to 70 °C 254 No 75% 2 No Yes Yes No No 79.4 Yes Fail-safe (NO / NC, depends... Electronic
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Flange F03, Flange F04,... 4-20 mA (modulating) Rotating 20 22.2 Yes Polyamide (PA) 10 14 4-20 mA, Open & close limit... 90 No 110 With cogwheels Yes Yes Yes IP67 Yes -20 °C to 70 °C 171 No 75% 2 No Yes Yes No No 39.6 Yes Fail-safe (NO / NC, depends... Electronic
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Flange F03, Flange F04,... 4-20 mA (modulating) Rotating 35 22.7 Yes Polyamide (PA) 10 11 4-20 mA, Open & close limit... 90 No 110 With cogwheels Yes Yes Yes IP67 Yes -20 °C to 70 °C 171 No 75% 2 No Yes Yes No No 45.9 Yes Fail-safe (NO / NC, depends... Electronic
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Flange F03, Flange F04,... 4-20 mA (modulating) Rotating 35 22.7 Yes Polyamide (PA) 10 14 4-20 mA, Open & close limit... 90 No 110 With cogwheels Yes Yes Yes IP67 Yes -20 °C to 70 °C 171 No 75% 2 No Yes Yes No No 45.9 Yes Fail-safe (NO / NC, depends... Electronic
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Flange F03, Flange F04,... Three-point (open-close) Rotating 20 22.2 Yes Polyamide (PA) 10 14 None 90 No 110 With cogwheels Yes Yes Yes IP67 Yes -20 °C to 70 °C 171 No 75% 2 Yes No Yes No No 39.6 Yes Fail-safe (NO / NC, depends... Electronic
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Flange F05, Flange F07 Three-point (open-close) Rotating 55 21.1 Yes Polyamide (PA) 15 14 None 90 No 110 With cogwheels Yes Yes Yes IP67 Yes -20 °C to 70 °C 196 No 75% 2 Yes No Yes No No 48 Yes Fail-safe (NO / NC, depends... Electronic
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Flange F03, Flange F04,... 4-20 mA (modulating) Rotating 20 22.2 Yes Polyamide (PA) 10 9 4-20 mA, Open & close limit... 90 No 110 With cogwheels No Yes Yes IP67 Yes -20 °C to 70 °C 171 No 75% 2 No Yes Yes No No 39.6 Yes - -
J3C Modulating 24-240V...
+9 days